+387 33 475 850info@alternativa.baMon–Fri 07:30–16:15

Certificates and standards

Quality and responsibility
Alternativa

Three ISO standards for the way the company works, a European standard and the CE marking for what leaves the hall. All of them are issued and checked by somebody outside — which is why they count.

2005the first ISO certification
3ISO standards in the system
First, to be clear

These are not documents about the same thing

Certifies the company

ISO 9001 · 14001 · 45001

They speak to how the work is done: whether procedures exist, whether what matters is measured, what happens when something goes wrong. They do not refer to any particular panel but to the house that makes it.

Travels with the product

EN 14509 · CE

They say what a particular product can do: how much it carries, how well it insulates, how it behaves in a fire. The figures are measured to the standard and set out in the Declaration of Performance that goes with the delivery.

What we hold and what it means

Five documents, one by one

Management system

ISO 9001:2015 — Quality management

It does not claim that a panel is good — it claims that a system exists to keep that under control: who does what, what is measured, what happens when something falls outside tolerance and how a complaint is closed. At Alternativa it has been in place since 2005, longer than any other standard.

Applies to
the whole company and every plant
In place since
2005

ISO 14001:2015 — Environmental management

It requires records of waste and emissions, a plan for what is done with them, and evidence that the plan is followed. That is why the solar plant on the hall roof and the filters on the furnace are not a statement of good intentions but items that someone from outside comes to check.

Covers
waste, emissions and consumption in production

ISO 45001:2018 — Occupational health and safety

A system for preventing injuries: a risk assessment for every workplace, training, protective equipment and an investigation of every incident — including the one that passed without consequence. On lines running three shifts, that is the difference between a rule and a piece of paper.

Applies to
every workplace in the plants
Requires
risk assessment and investigation of incidents

Product

EN 14509:2013 — The standard for sandwich panels

The European standard by which self-supporting panels with metal facings are made, tested and declared — from the strength and shear of the core, through load capacity, to reaction to fire. A panel that has not been tested to it may not carry the CE marking.

Full designation
BAS EN 14509:2014 (EN 14509:2013)
Assessment system
System 3
Reaction to fire tested by
FIRES s.r.o., Slovakia

CE — The marking of conformity

CE is not a quality mark but a manufacturer’s declaration — given under Regulation (EU) No 305/2011 — that the product has exactly the properties stated for it, measured to a harmonised standard. That is why a Declaration of Performance with figures comes with the delivery, not an assurance.

Basis
Regulation (EU) No 305/2011 (CPR)
Panels to
EN 14509 — system 3
Sheets to
EN 1090 — system 2+, body 0090
CE in practice

A Declaration of Performance with every delivery

Behind the CE marking stands one sheet of paper per product. It says which standard the product was assessed to, who checked it and — most important — what values the manufacturer declares. Here are two real ones, from our own production.

Declarations of Performance with the CE marking for a panel and a trapezoidal sheet
057-CPR-TOPTERM ZP 180 RW

Topterm ZP 180 RW

Metal-faced thermal insulating panel for walls and wall cladding

BAS EN 14509:2014System 3
U-value
0.191 W/m²K
Conductivity of the core
0.035 W/mK
Reaction to fire
A2 – s1, d0
Fire resistance
EI 180
1200-CPR-TR 152/288 ATLAS – 0,75

Trapezoidal profile TR 152/288 Atlas

Load-bearing profiled sheet for floors and roofs

BAS EN 1090-1+A1:2012System 2+
Material
S320GD (1.0250)
Coating
AZ 100
Reaction to fire
Class A1
Execution class
EXC 2
Who checks

Independent certification and surveillance

Certificates are issued by accredited bodies, and compliance is checked through regular surveillance audits.

TÜV Thüringen e.V. (TIC), Jena

Certifies the management system to all three ISO standards and returns for regular surveillance audits. Accredited by the German accreditation body DAkkS.

FIRES s.r.o., Slovakia

The notified body that tested the reaction of the panels to fire — the part without which the declared fire classes would have no backing.

Notified body 0090

For profiled sheets to EN 1090, factory production control is confirmed by TÜV Thüringen under number 0090, certificate 090.CPR-1090-1.0011.TÜVTH.2022-01.

Issued
Jena, 3 April 2024
Accreditation
DAkkS · D-ZM-16006-05-01, -02, -04
Surveillance
regular surveillance audits

Need a document for a project?

We send the Declaration of Performance, the data sheet or a copy of a certificate on request — just tell us the product and the thickness.

Alternativa / Documentation

Knowledge for your next project.

Explore our range, prepare for installation and find technical information in one place.

02
From preparation to installation

Installation manual

Practical guidance for installing Topterm panels correctly.

03
Information for your design

Technical data sheet

Technical characteristics for your selected panel model.

The catalogue is available now. Other documents are supplied on request.